GT9000 Central Monitoring System
The diversification of the layout of the monitoring fulfills different requirements
Important monitoring can be done while other beds are also monitored
Real-time trend graphs
Powerful data playback including those of ECG, PLETH and RESP
Providing the records of hospitalization and creating the medical records according to the requirements
The monitoring system on Windows 2000 Professional,
with powerful functions, stability, reliability and flexible interface.
Monitoring 1 to 8 beds.
Real time monitoring of the patients' information.
A breakthrough.
Monitoring and saving the patient's information
without the time limitation.
Perfect menu system,
flexible mouse operation and real time prompts.
Multi views for monitoring the patient.
Displaying all the monitored information at the same time.
The waveform can be frozen and the monitored data
can be selected at will.
Multi layouts for the monitoring. Meeting the different needs.
Recording all the parameters of the patient.
Important monitoring can be done
while monitoring other beds at the same time.
Providing real time trend graphs.
Powerful data playback including those of
ECG, PLETH and RESP and trend display.
Providing the quick operation of the records of hospitalization and creating the medical records according to the requirements.
Provided with the ink jet printer for the real time printing and the printing of the playback and medical record.
Flexible network configuration.
Both-way communication with the monitor beside the patient's bed can be available.
--------------------------------------------------------------------------------
Fetal/Maternal Monitor
Specifications of GT9000 Multi-Parameter Monitor
(Standards of IEC60601 and GB9706)
Operating:
Temperature 5~40 degrees Celsius Humidity = 80%
Storage: Temperature -20~55 degrees Celsius Humidity = 93%
Battery: Built-in rechargeable battery,
maximum utility time = 2 hours
Trend Observation: 1~72 hours trend graphics
Network: Compatible with central monitoring system
Recorder: Built-in, thermal
Recording Modes: Manual, alarm and timing
Ultrasonic Probe:
(Fetal Heart Rate)
Type B Proof, Directional
Using Pulse Doppler system
Working Frequency: 2.5MHz
Transmitting Power Density:
1.2m W/cm2
Using the multi-wafer probe
Sampling Rate: ±5ms
Calculating Precision of Fetal Heart Rate: ±0.25bpm
Accuracy of Fetal Heart Rate: ±1bpm (100-180bpm)
Marker
(Fetal Movement)
Manual Push Button Mode
(Operated by the monitored person) .
When pressed, a red strip will be displayed above
the Fetal Heart Rate graph.
Uterine Contraction Pressure
Type B Proof
Uterine Contraction Pressure probe
Manual Zero Adjustment
Design Pressure Sensitivity: 0-100%ECG
Displaying graphics of 7 leads on the same screen
Overload protection: Defibrillation.
Anti the interference of high-frequency electrotome
Lead: 5 leads (R, L, F, N, C)
Lead Selection: I; II; III; avR; avL; avF; V;
Waveform: 7 channels
Gain Selection: ×0. 5; ×1; ×2; ×4
Electrical Leakage : < 30uA
Baseline Recovery Time: <3 sec following
defibrillation
Protection: separates and withstands
4000V AC/50Hz defibrillation,
resistant to interference of electrotome
and myoelectricity
Scan Speed: 12.5mm/25mm/50mm/sec
Lead Drop: auto detection
Modes: DIA: 0.05~100Hz
MON: 0.5~35Hz
OPE: 1~25HzRESP
Model: RA-LL impedance
Measurement /alarm range:1-99 rpm
Resolution: 1rpm.
Accuracy: ±2rpm.
TEMP
Resolution: 0.1 degrees Celsius
Accuracy: ±0.2 degrees Celsius
Channel: 2 channels
Average measurement Time: < 10sec
Alarm: Sound, light
NIBP
Unique Direct, Reverse and Quick modes
Method: automatic oscillometric
Working Mode: Auto/Manual
Interval of Auto Mode: 1-60 min
PR Range: 0-300 bpm
Measurement Unit: mmHg/Kpa Selectable
Measurement Ranges: Systolic BP,
Diastolic BP and Mean BP
Applicability: Adult/Pediatric/Neonatal
Overload protection: Dual security protectionSpO2
SpO2 probe of high intensity and durability
Excellent measurement of low perfusion.
Anti interference of movement
Measurement Range: 0-100%
Alarm range: 0-100%
Resolution: ±1%
Accuracy: ±2% (80-100%)
±3% (60-79%)
PR range: 0~300bpm
HR
A. Measurement Range: 0-300bpm
B. Accuracy: ±1bpm or ±2%
C. Resolution: 1bpm
D. ECG Calibration: 1mV (Peak Value)
ST Segment offset (Diagnose Mode)
A. Measurement Range: -0.8mV~2.0mV
B. Accuracy: ±0.02mV or ±5%
Standard Equipment: Uterine Contraction Pressure + Fetal Movement + ECG + NIBP + SpO2 + RESP + PR + TEMP + Built-in Battery
Optional Equipment: Built-in thermal printer + dual channel Temp probe.
--------------------------------------------------------------------------------
GT9000C
Technical Parameter
12.1" color LCD display
Advanced technology of digital signal processing
Real-time computerization & mode identification
Built-in thermal printer for printing of graphics and parameters
High sensitivity, probe with wafers
Excellent signal-noise ratio of the system and accuracy of processing
Displaying ECG, NIBP, SPO2 , RESP, TEMP and PR
GT9000C
Specifications of GT9000 Multi-Parameter Monitor
(Standards of IEC60601 and GB9706)
Operating: Temperature 5~40 ? Humidity = 80%
Storage: Temperature -20~55 ? Humidity = 93%
Battery: Built-in rechargeable battery,
maximum utility time = 2 hours
Trend Observation: 1~72 hours trend graphics
Network: Compatible with central monitoring system,
Recorder: Built-in, thermal
Recording Modes: Manual, alarm and timing
ECG
Displaying graphics of 7 leads on the same screen
Overload protection: Defibrillation.
Anti the interference of high-frequency electrotome
Lead: 5 leads (R, L, F, N, C)
Lead Selection: I; II; III; avR; avL; avF; V;
Waveform: 7 channels
Gain Selection: ×0. 5; ×1; ×2; ×4
Electrical Leakage : < 30uA
Baseline Recovery Time: <3 sec following
defibrillation
Protection:separates and withstands
4000V AC/50Hz defibrillation,
resistent to interference of electrotonus
and myoelectricity
Scan Speed: 12.5mm/25mm/50mm/sec
Lead Drop: auto detection
Modes: DIA: 0.05~100Hz
MON: 0.5~35Hz
OPE: 1~25Hz
RESP
Model: RA-LL impedance
Measurement /alarm range:1-99 rpm
Resolution: 1rpm.
Accuracy: ±2rpm.
NIBP
Unique Direct, Reverse and Quick modes
Method: automatic oscillometric
Working Mode: Auto/Manual
Interval of Auto Mode: 1-60 min
PR Range: 0-300 bpm
Measurement Unit: mmHg/Kpa Selectable
Measurement Ranges: Systolic BP,
Diastolic BP and Mean BP
Applicability: Adult/Pediatric/Neonatal
Overload protection: Dual security protection
SpO2
SpO2 probe of high intensity and durability
Excellent measurement of low perfusion.
Anti interference of movement
Measurement Range: 0-100%
Alarm range: 0-100%
Resolution: ±1%
Accuracy: ±2% (80-100%)
±3% (60-79%)
PR range: 0~300bpm
HR
A. Measurement Range: 0-300bpm
B. Accuracy: ±1bpm or ±2%
C. Resolution: 1bpm
D. ECG Calibration: 1mV (Peak Value)
ST Segment offset (Diagnose Mode)
A. Measurement Range: -0.8mV~2.0mV
B. Accuracy: ±0.02mV or ±5%
TEMP
Resolution: 0.1 degrees Celsius
Accuracy: ±0.2 degrees Celsius
Channel: 2 channels
Average measurement Time: < 10sec
Alarm: Sound, light
Standard Configuration: ECG + RESP + NIBP
+ SpO2 + HR(PR) + Dual TEMP
+ Built-in Battery
Optional Equipment: Maternal/Fetal Monitoring,
End Tidal Co2, Built-in Thermal Printer
Category :
Patient Monitors
Related Searches :
Country Of Origin :
China
Listing Type :
Sell
Brand Name :
Gotom/GT
Condition :
new
Certifications :
ISO.MC,CCCI,UKAS
Dimensions :
330mmx280mmx150mm
Weight :
6.5kg
Colors :
blue/green
Power :
A,C.220V-240v,50HZ
Supply Capacity :
500 Units Per Month
Contact :
KRIS SU
Address :
6/F., Three-Dimension Science&
Technology Building,No.184 Bai
Lian Road,Jida, Guangdong, 519015
China
Telephone :
[86] (756) 3883962
Fax :
[86] (756) 3321880