Sell Communication Manager

Communication Manager You May Also Be Interested In: commercial real communication device industrial computer levers rs 422
SPC3000 series communication manager is a high integrated new 32bit embedded intelligent communication device. It is used to collect information of whole substation automation system and centralized send to local back-end or remote debug centre, and at the same time transfer the orders of back-end and centers to all measure and controll devices that realize local and remote control. SPC directly collect all on-site device data in small sized automation system, and transfer to background control system by user required communication protocol( 101,104, CDT and so on) and communication medium(ethernet, RS232/422/485 and so on) to finish all on-site monitoring. In big systems, it can be as function substation and bay level that make all levers relatd to realize data transferd through different classification and directions.
To adopt Motorala 32-bit high performance microcontrollers and commercial real-time multifunction operating system that make sure of the product stability and operration speed.
High quality industrial element, high lever electrial design and high density integrated circuit structure enable the device have excellent electro-magnetic shielding and electrical isolation. The integrated machine has no regulable element that greatly enhance the ability of anti-interference and the reliability of the device.
Adopt good performance switch power to the device, input voltage is DC 110~340V or AC 85~264V, output voltage is 5V, wide-range voltage output can widely be used for different power supply enviroment.
Having high speed and reliable communitation interface such as ethernet and serial port and CAN for system extension to strengthen the device scalability and allocation flexibility.
Flexible on-line and off-line debugging, reliable program upgrading and parameter download and data query functions meet the need of ever new and faster network information age.
Be provided with great ability of self diagnosis and self healing, the system can be self-recoverd in a short time when causing program operation error by outside interference or other reasons.
Provide secondary development kit, on the basis of supporting CDT, Polling, Modbus, DNP 3.0, 1801, IEC870-5-101/102/103/104 and communication prococol of home-abroad main electrical power producer, it can develop special protocol according to on-site demand.
Provide many kinds of lever-related working way that makes the system extension and compounding more convenient and flexible.
Offer active-standby redundancy and switch function to meet all needs of safety which user concerns.

Use real time operation system Nucleus as the platform, realize multifunction, on the basis of communication program of message queuing, face all objects:object programmer, communication port and communication protocol seperately. The communication function can be real time and reliable.
Standard 191U upper-locacted, beautiful style and convenient screen.
Predominant performance to price ratio. One device is equal to the total of industrial computer, SCADA software, serial device server and switch, and never be in the Dead State, more convenient for users local application and market competetion.
System index Work environment requirement
 System availability
System availability>=99.98%
 System capacity

 Insert device qty one time: <=64 insert element supports decentralized installation.

 Transmission debug qty one time: <=3
 Ability of inserting communication
a) Support RS-232, RS-422, RS-485 communication
b) Support Lan communication, conform to IEEE802.3 stipulation, use TCP/IP as the basic net communication protocol.
 c) Support CAN bus communication
 Communication ability with debug
a) Support synchronous digital series SDH transfer, support G.703
b) Support microwave relay communication
 Information transmission time
 Action protection event<=3s
 Failure report<=10s
Query response time <=5s

 Environment temperature: -100~+500, the average temperature can not surpass +350 in 24 hours;
 Storing temperature: -10 0 ~+70 0, no increase to excitation under the limit value, no irreversible conversion to the device, after the temperature resuming, the device can work normally;
 Relative humidity: less than 85
 Air pressure: 80 kPa ~110kPa
 Working place: deviate the datum location less than 5
 There should not be explosive medium, either the gas which can corrode the metal and destroy the insulation or conductive media; can not fill with vapor and exist serious mold;
 The application place must have the facilities to defend rain , snow , wind, sand and dusty.
Condition of Goods
Lead Time from Order to Shipment
Minimum Order Quantity