Model: KP45 / KP50E
Prime power (kVA) : 45 / 50
Prime power (kW) : 36 / 40
Rated power factor: 0.8 (lagging)
Rated voltage (V) : 400/230
Rated current (A) : 68 / 76
Gen set size (LWWWH) (mm) : 1750W710W1331
Sub-foundation size (LWWWH) (mm) : 1950W910W100
Gen set gross weight (kg) : 878
Capacity of basement fuel tank (L) : 180

ENGINE Perkins (China)
Model : 1004G Rated speed (RPM) : 1500
Cylinder number: 4 Rated power (kW) : 44.1
Cylinder layout : L
Recommended fuel: NO.0 of China
Bore/stroke (mm) : 100/127
Fuel consumption (L/h) : 11.3 / 13.9
Total displacement (L) : 3.99
Fuel consumption (g/kwh) : <=208
Combustion ratio: 16:1
Recommended oil : API-CD OR BETTER
Aspiration: Nature
Oil system capacity (L) : 8.1
Governor: Mechanic
Oil consumption (L/h) : 0.069
Mode of start: Battery DC24V
Oil normal temperature (0) : 105
Allowable restriction (kPa) : 6
Max. Exhaust temperature (0) : 680
Mode of Cooling : Cycling water
Air Consumption (m3/min) : 2.64
Capacity of cooling water: 21
Exhaust flow (m3/min) : 8
Normal temp. of cooling water (0) : 70-80 Exhaust pipe diameter (mm) : 63.5
Cooling water Flow (L/sec) : 1.33
Air flow from radiator (m3/min) : 150

GENERATOR
Manufacturer: NEWAGE (STAMFORD)
Model : UCI224D
Exciter : Brushless and self excited
Voltage adjust scope: >=16%
Stable Voltage regulation: <=11.0%
Temp. rise : H Voltage control : AVR (SX440)
Insulation class: H
Overload capacity: 1.5 rated current/2 min.
Protection: IP22 Short
circuit capacity: 3 rated current/10 sec.
Efficiency: 87.6% Cooling model: Natuure
Phone interfere rate: THF<2%, TIF<50
Rotor type: Protruding