Sell Double ended beams load cell (BM-LS)

Double ended beams load cell (BM-LS) You May Also Be Interested In: cell insulation resistance load cell truck scale
Major uses
It has good compatibility and can be conveniently installed. Suitable for truck scale, track scale, hopper scale and other special scales for weighing and force measurement.

BM-LS type load cell has peculiar structure of both ends supporting, center forced. This structure enables the load cell to have high accuracy and high reliability in measuring.
Force is transferred by pressure head and steel ball which can automatically recover and correct core. The elastic body is made of alloy steel. Cross-range force and impulsive force can be well resisted. Sealed hermetically with damp-proof material, the load cell can work properly in adverse circumstances and has protection grade specified as IP68. It is able to be used in explosive dangerous circumstance. The explosion-proof symbol is ExibIIBT6.
It has received certificate of OIML and NTEP approval.

Product Details:
Place of Origin: Shandong China
Brand Name: Goldbell
Model Number: BM-LS
Payment & Shipping Terms:
Minimum Order Quantity: 12 Piece/Pieces
Delivery Time: within 30 days after receipt of order
Payment Terms: L/C, T/T
Supply Ability: 5000 Piece/Pieces per Month

Detailed Product Description

Capacity t 3, 5, 10, 20, 25, 30, 50
Sensitivity mV/V 2.010.004
Accuracy class C3 C2 0.05
Maximum number of load cell interval 3000 2000
Minimum load cell verification interval Emax /10000 Emax /7000
Combined error %F. S. 0.02 0.023 0.05
Repeatability %F. S. 0.01 0.015 0.03
Creep %F. S. / 30min 10.0245 10.0245 10.05
Minimum dead load output return %F. S. 10.017 10.025 10.05
Temp. effect on min. dead load output %F. S. / 5 10.007 10.010 10.025
Temp. effect on sensitivity %F. S. / 5 10.007 10.009 10.025
Minimum dead load %Emax 1
Maximum safe overload %Emax 150
Ultimate overload %Emax 200
Supply voltage V 10 ~ 15 ( DC/ AC)
Zero balance %F. S. 11
Input resistance (Ohms) 770 ~ 830
Output resistance (Ohms) 697 ~ 706
Insulation resistance M(Ohms) >= 5000
Compensated temperature range -10 ~ +40
Operating temperature range -30 ~ +70
Connect cable mm 6.7 * 13000 ( 10t: 9000)
Method of connecting wire Input(+) : Red Input(-) : White
Output(+) : Green Output(-) : Blue
Shield: Yellow