Sell Motor Installation and Test Training Equipment

Motor Installation and Test Training Equipment You May Also Be Interested In: dielectric strength tester digital ammeter power calculation test equipment training equipment
1. The training consists of fundament, technology, machining and assembly, check of motor fitter, it is suitable for colleges and vocation schools for corresponding teaching and skill training.
2. The instruments are fixed on the bench-top control panel.
3. Corresponding tools and instrument are available.
4. Modular design for easy studying of skill training and theory.
5. Fully safety protection for open lab.

Equipment list
1. Three-phase four-wire power supply controlled by start/stop buttons with leakage breaker and main power switch, and there is a emergency button for quick stop.
2. One digital AV voltmeter on the panel is used for 3-phase power grid indication adjusted by band-switch.
3. Timer/alarm recorder, used as a timer as usual with function of time setting, timing alarming, power cutting off and lab service supervision by faults recording (leakage fault, over range fault etc. ) .
4. Three-phase variable AC power supply: 0~450V/5A from variable transformer
5. DC power supply: 30V/2A DC variable stabilized power supply with short-circuit protection.
6. One DC digital voltmeter: Measurement range: 0~1000V overlapping in 2V/20V/200V/1000V controlled by keys, input impedance: 10M(Ohms); auto-ranging, accuracy: class 0.5, -digit display with over-range alarming, indication and power cutoff.
7. One DC digital milliammeter: Measurement range: 0~2000mA, accuracy: class 0.5, -digit display with over-range alarming, indication and power cutoff.
8. One RMS value AC digital voltmeter: Measurement range: 0~500V, auto-ranging, accuracy: class 0.5, -digit display.
9. Three RMS value AC digital ammeter: Measurement range: 0~5A, auto-ranging, accuracy: class 0.5, -digit display with over-range alarming, indication and power cutoff.
Intelligent power, power factor meters: Constructed by microprocessor, high-speed A/D conversion chip and fully digit-displayed circuits. Intelligent control is obtained by keys and digit display. The sample signal of measured voltage and current are sent to DSP after A/D conversion for positive/active power calculation. Measurement of single/three-phase power with accuracy of grade 0.5 and ranges of voltmeter and ammeters are 450V, 5A. also, data can be recorded and inquiry. The total power is obtained by sum of P1+P2.
Lab exercises:
Assembly of asynchronous motor
1. Inserted line and connection of asynchronous motor wind
(1) Inserted line of concentric winding
(2) Inserted line of chain winding
(3) Inserted line of cross chain winding
(4) Inserted line of double-layer short winding
(5) Inserted line of double-layer wave winding
(6) Inserted line of double-layer concentric winding
2. Impregnating of Insulating Process
3. Stator assembly of asynchronous motor
4. Rotor assembly of asynchronous motor
5. Fully assembly of asynchronous motor
6. Correction of motor axis
7. Dynamic balance of rotor
8. Mechanical check of motor
9. Check of windings
(1) Appearance and dimension check
(2) Current balance test of 3-phase windings
(3) Anti-voltage test
Assembly of salient pole synchronous motor
1. Stator assembly of salient pole synchronous motor
2. Inserted line of stator of salient pole synchronous motor
3. Rotor assembly of salient pole synchronous motor
4. Inserted line of rotor of salient pole synchronous motor
5. Fully assembly of salient pole synchronous motor
6. Dynamic balance of rotor
7. Mechanical check of salient pole synchronous motor
8. Check of windings
(1) Appearance and dimension check
(2) Current balance test of 3-phase windings
(3) Anti-voltage test
Assembly of DC motor
1. Stator assembly of DC motor
2. Stator winding of DC motor
3. Armature assembly of DC motor
4. Inserted line of armature winding of DC motor
5. Fully assembly of DC motor
6. Mechanical check of DC motor
7. Check of windings
(1) Appearance and dimension check
(2) Anti-voltage test
(3) Check of DC armature windings
DC power supply 30V/2A variable DC stabilized power supply with short-circuit protection.
DC digital voltmeter Measurement range: 0~1000V overlapping in 2V/20V/200V/1000V controlled by keys, input impedance: 10M(Ohms); auto-ranging, accuracy: class 0.5, 3 and 1/2digit display with over-range alarming, indication and power cutoff.
DC digital milliammeter Measurement range: 0~2000mA, accuracy: class 0.5, 3 and 1/2 digit display with over-range alarming, indication and power cutoff.
RMS value AC digital voltmeter Measurement range: 0~500V, auto-ranging, accuracy: class 0.5, 3 and 1/2 digit display.

RMS value AC digital ammeter Measurement range: 0~5A, auto-ranging, accuracy: class 0.5, 3 and 1/2 digit display with over-range alarming, indication and power cutoff.
Intelligent power, power factor meters Constructed by microprocessor, high-speed A/D conversion chip and fully digit-displayed circuits. Intelligent control is obtained by keys and digit display. The sample signal of measured voltage and current are sent to DSP after A/D conversion for positive/active power calculation. Measurement of single/three-phase power with accuracy of grade 0.5 and ranges of voltmeter and ammeters are 450V, 5A. also, data can be recorded and inquiry. The total power is obtained by sum of P1+P2.
Tools 1. Tools for removing and mounting: puller, adjustable wrench, hammer ram, marking off plate, pressing line plate, scissors, screwdriver, chisel, nipper pliers, blade, feeler gauge, file, chamfering tool, rose reamer, wire stripper and soldering iron etc.
2. Manual electric-counted coiling machine: precision counting and easy reading, precision counting of 0~9999 circle.
3. Winding former for 3-phase motor
4. Un-impregrated 3-phase squirrel-cage asynchronous motor, rated power: 1.1kW; voltage: 380V (Y connection) ; current: 2.7A, rotation speed: 1400r/min.
5. Un-impregrated separated-excited motor, rated power: 200W; voltage: 220V; current: 1.2A, rotation speed: 1500r/min.
6. Un-impregrated synchronous motor: rated power: 120kW; voltage: 380V (Y connection) ; current: 0.35A, rotation speed: 1500r/min
500V megameter Used for insulation resistance measurement of transformer and motor windings,
AC dielectric strength tester 1. Voltage measurement range: 0~5kV15%13 digit
2. Leakage current measurement range (mA) : 0.3~2~20~10015%13 digit
3. Alarm setting leakage current range(mA) : 0.3~2~20~10015%13 digit
4. Timing setting range: 1~99S15%, or manual control\
5. Transformer capacity: 1000VA
Short-circuit tester 1. Oscillation frequency (f) : 700Hz~1000Hz, with no load
2. Pulse amplitude (Vp-p) : 0~200Vp-p, probe short-connected
3. Sensitivity: >3mm, with probe near the tested circuit
4. Alarming volume output power (P) : >100mW, with the max. test intensity.
Clamp-on meter 1. AC voltage: ACV 5/25/50/250V 15%
2. AC current: ACA 300/600V 15%
Analog multimeter 1. DC voltage: DCV 0/2.5/10/50/250/500/2500V
2. DC current: DCA 0/50UA/1/10/100/500MA
3. AC voltage: ACV 0/10/50/250/500/2500V
4. Resistance: RW1 RW10 RW100 RW1K RW10K(Ohms)
Digital multimeter 1. DC voltage: 200mV/2V/20V/200V/1000V 1(0.5%+3)
2. AC voltage: 2V/20V/200V/750V 1(0.8%+5)
3. DC current: 20uA/2mA/200mA/20A 1(1.5%+3)
4. AC current: 2mA/20mA/20A 1(1.5%+5)
5. resistance: 200(Ohms)/2k(Ohms)/20k(Ohms)/200k(Ohms)/2M(Ohms)/20M(Ohms) 1(0.8%+5)
6. conductance: (0.1-100) nS 1(1.0%+30)
7. capacitance: 20nF/200nF/20uF/200uF 1(4.0%+10)
8. Frequency: 20kHz 1(1.5%+25) temperature: -400-10000 1(0.75%+3)
9. Special function: diode test, triode test, on/off alarm, low-voltage display, data hold, self-turning off, functional protection, self-recovery insurance, shakeproof, 10M(Ohms) input impedance, 3 times/s sample rate, 40-400Hz AC frequency response, manual operation and the maximum display is 1999.