Sell Multifunction power meter -YD2200

Multifunction power meter -YD2200 You May Also Be Interested In: multifunction meter multifunction power meter power meters
Model No. : YD2200
Brand Name: yadata
Certification(s) : CE

Features:
1) Functions:
a) Measures parameters of 3I, 3V, 3U, PF, F, P, S, 1Σ Wh and 1Σ Qh
b) Large screen digital LCD display
c) Functions of DC4 - 20mA, switch capacity, harmonic wave measuring, impulse output through insert different module, 4 modules available at most at the same time
2) Plug-in module names, models and functions behind the meter:
a) Communication output module (model YM-485) , RS485 communication function, communication protocol MODBUS-RTU
b) Analog quantity output module (model YM-A20) : set any power parameter through key-press or IPC (I, U, P and F) corresponding to DC4 - 20mA output, output load ability <=600(Ohms)
c) Switch capacity module (model YM-K2) : function of 2-route in and 2-route out, through connect this module YD2200 power meters can realize remote control, relay contact capacity is 220V, 5A
d) Electric energy pulse output module (model YM-E2) : function of active power electric energy and reactive power electric energy pulse output, each kWh or kVarh corresponding pulse numbers may choose at the range of 1,000 - 5,000pulses/kWh (kvar)
e) Electric energy pulse output module + harmonic analysis module (model YM-EX) : function of active power electric energy and reactive power electric energy pulse output, each kWh or kVarh corresponding pulse numbers may choose at the range of 1,000 - 5,000pulses/kWh (kvar) , realizing 1 - 19 times harmonic analysis
3) Technology indexes:
a) Standards: GB/T13850-1998, IEC688:1992, DL/T721-2000, IEC61000-4
b) Accuracy:
i) U, I, power, power factor: <0.5%RD
ii) Active electric energy, reactive electric energy, phase voltage: <1.0%RD
iii) Frequency: <=1.0% RD
c) Display units: V/kV/MV, A/kA, W/kW/MW/GW, Hz, var/kvar/Mvar, VA/kVA/MVA/GVA, Wh/kWh/MWh/varh/kVarh/Mvarh
d) Input range:
i) U: 5 - 120V / 600V (max. 600V)
ii) I: 0 - 1A / 5A (max. 6A)
e) Absorbing power consumption:
i) Voltage per route: <0.4VA (347V) / 0.2VA (150V)
ii) Current per route: <0.1VA (5A)
f) Overload capability:
i) U: 750V continuum / 1,000V 10s / 1,200V 3s
ii) I: 2 times rating continuum / 10s rating 30s
g) Measuring system: connection mode 3P4W / 3P3W / 1P2W, 1P3W /3P3W, balance / 3P4W balance, may set parameters by software through keyboard and serial port
h) Programmable setting: programmer mode (password)
i) Measuring system choice: 3P4W, 3P3W, 1P2W, 1P3W, 3P3W balance,3P4W balance, and CT, PT variable ratio 1 - 10,000
j) Display content: form feed time / menu with options
k) Communication:
i) Baud ratio: 1,200 / 2,400 / 4,800 / 9,600 / 19,200
ii) Parity bit: odd / even / no parity bit

m) Electric energy accumulating reposition: needs password