Sell Patient Monitor MD9000A: 12.1 inch

Patient Monitor  MD9000A: 12.1 inch You May Also Be Interested In: 12.1 inch avl monitor patient monitor pressure transducer
Patient Monitor (MD9000A: 12.1 inch ECG 3/5 Leads, SPO2, NIBP, TEMP. ) :
12.1 inch Monitor Size;
Color TFT Screen capable to display the waveform of up to 8 channels;
Light and portable . with build-in recharging battery for uninterrupted monitor;
Chinese-English interface operated easily by knobs;
UP to 10 kinds of monitor parameters;
Arrhythmia analysis, pace-marker detection and S-T segment analysis;
72 hour storage and review of trend grams and tables,40 second review of holographic waveforms;
Other bed observation and power failure storage;
Double screen display and network widely applied to the monitor of patient under operation and centralized monitor of gravis;
Built-in recorder (option) ;
All-round monitor of adult, pediatric and neonatal;
electrosurgical unit and defibrillation protected.

Specification:
5-lead or 3-lead selectable
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: I; II; III; avR; avL; avF; Vx; CAL
Gain selection: x0.25; x0.5; x1; x2; auto
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Accuracy: 11bpm or 11%, whichever is greater
Protection: Withstand 4000VAC/50Hz voltage
in isolation against electrosurgical interference and defibrillation
Calibration signal: 1mV15%
Operation modes: Diagnostic, Monitor, Surgery
Alarm range: Adult: 15-300bpm
Pediatric/Neonatal: 15-350bpm
S-T detection: YES
Alarm range: -2.0mV~2.0mV
Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable
NIBP:
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/KPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
Alarm: Systolic, Diastolic, Mean
SpO2:
Measurement range: 0-100%
Accuracy: 12digit (70~100%) ;0~69% unspecified
Alarm range: 0-100%
Respiration:
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/KPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg

Temperature:
Resolution: 0.10
Channel: Dual-channel
Alarm range: 0-500

Options:

EtCO2:
Measurement Mode: Sidestream or mainstream (optional)
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration
Apnea alarm: YES

CO
Method: Thermodilution
Measurement range: CO: 0.1-20 lit. /min.

IBP
Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: -10~300mmHg