Sell Patient Monitor MD9000B: 10.4 inch

Patient Monitor  MD9000B: 10.4 inch
Patient Monitor (MD9000B: 10.4 inch ECG 3/5 Leads, SPO2, NIBP, TEMP. ) :
10,4 inch Monitor Size
Color TFT Screen capable to display the waveform of up to 8 channels
Light and portable . with build-in recharging battery for uninterrupted monitor
Chinese-English interface operated easily by knobs
UP to 10 kinds of monitor parameters
Arrhythmia analysis, pace-marker detection and S-T segment analysis
72 hour storage and review of trend grams and tables,40 second review of holographic waveforms.
Other bed observation and power failure storage
Double screen display and network widely applied to the monitor of patient under operation and centralized monitor of gravis.
Built-in recorder (option)
All-round monitor of adult, pediatric and neonatal
electrosurgical unit and defibrillation protected
Specification:
ECG:
5-lead or 3-lead selectable
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: I; II; III; avR; avL; avF; Vx; CAL
Gain selection: x0.25; x0.5; x1; x2; auto
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Accuracy: 11bpm or 11%, whichever is greater
Protection: Withstand 4000VAC/50Hz voltage
in isolation against electrosurgical interference and defibrillation
Calibration signal: 1mV15%
Operation modes: Diagnostic, Monitor, Surgery
Alarm range: Adult: 15-300bpm
Pediatric/Neonatal: 15-350bpm
S-T detection: YES
Alarm range: -2.0mV~2.0mV
Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable
NIBP:
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/KPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
Alarm: Systolic, Diastolic, Mean
SpO2:
Measurement range: 0-100%
Accuracy: 12digit (70~100%) ;0~69% unspecified
Alarm range: 0-100%
Respiration:
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/KPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg

Temperature:
Resolution: 0.10
Channel: Dual-channel
Alarm range: 0-500

Options:

EtCO2:
Measurement Mode: Sidestream or mainstream (optional)
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration
Apnea alarm: YES

CO
Method: Thermodilution
Measurement range: CO: 0.1-20 lit. /min.

IBP
Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: -10~300mmHg