Sell Photosensitive 100 Series Optical Power Meter

Photosensitive 100 Series Optical Power Meter You May Also Be Interested In: attenuator meter optical power meter power meter
Photosensitive100 Series Optical Power Meter equips with wide angle detector, replaceable attenuator and various fiber adapters, which can be connected directly with the computer with USB or RS232 communication port. It is an intelligent but economical test device and very suitable for optical power measurements from Passive Components Producers, Research Lab and University Lab.
Product Features
 Wide angle Si, Ge detectors can be alternative
The Photosensitive100 series Optical Power Meter can support the detector size up to 5mm for Ge detector and 10mm for Si detector.
The measurement wavelength range is from 400~1100nm for Si detector and 800~1600 for Ge detector, with dynamic ranger of 60dB.
 Compensation of the detector temperature
Photosensitive100 series Optical Power Meter can calibrate the value of the testing result trough the detector temperature compensation; this will lessen the reading value offset caused by the external temperature change
 Various Optical Fiber Adaptors can be required
Photosensitive100 series Optical Power Meter provide the FC, SC, ST, LC and other kind of changeable optical fiber adaptors, can adapt for all kinds of the need of the optical fiber connection.
User-self Calibration Function
Any wavelength can be calibrated by user independently (up to 9 wavelengths calibration can be supported) . The device do not need to send back to the original factory for recalibration, it can be deal with in the local Measurement Bureau for the annually calibration.
Attenuation Chips can be changeable
Photosensitive100 series Optical Power Meter support 10,100 and 1000 absorbability attenuation chips, for the convenience of users variable attenuation requirements.
WIN32 API Support
Photosensitive100 series Optical Power Meter provide various API ports based on WIN32, so that the user can develop its own software according to its actual requirements, which includes:
1) Data Reading
Read the current wavelength power value (also can customize the relative log, absolute log, and linearity) , also can read the detector temperature
2) Calibration
Calibrate the current wavelength, zero calibration, and adjust the compensation temperature
3) Setting
Setting the wavelength, Setting the measurements mode (manual, Auto) , Setting the ranger, Setting the filter speed, Setting Units, Setting the reference value
Brand Name
Model Number
Minimum Order Quantity