Sell shell and tube heat exchanger

shell and tube heat exchanger You May Also Be Interested In: grooved copper tube leak detectors shell and tube heat exchanger shell tube shell tube heat exchanger
The UAR shell and tube condensers are designed, by using the best technical solutions, for applications in the fields of air-conditioning and refrigeration. The capacity range in nominal conditions is from 3 to 500 RT (from 13. 189 KW to 1934. 35 KW) . To rapidly and clearly understand our products definition, a table with the DEFINITION CODE has been prepared in which a series of variable standards and any particular customs made requests are drawn up. The shell and tube part is made of high performance tubes of special coppers, finned externally and grooved internally for a low fouling factor. With the combination of the two effects, refrigerant side and water-flow side, condensers are obtained that are reduced in size and weight compared to those e that use traditional tubes for the same capacity. Meanwhile, UAR is still being supported by many copper manufacturers for constantly improved new copper which applied in heat exchangers. All the products are made to function with tap water, well water or on request sea water.


The materials, the welding and the manufacturing process controls conform to directives of the National Compress Vessels Association as BR1 Grade and the ISO 9001: Ed. 2000 quality assurance system that regulate and direct the construction of pressurized vessels.
--Tubes: Externally finned and internally grooved copper tube;
--All components are in carbon steel and copper tube connection;
--The asbestos-free gaskets used are suitable for use with HCFC and HCF refrigerants


UAR shell and tube condensers have undergone a hydraulic pressure test equal he quality manual ISO 9001: Ed. 2000 and specifically, all the products should be tested undergo:
--Pressure testing on the refrigerant side;
--Pressure testing on the water-flow side;
--Leak testing with leak detectors.


In the Shell and Tube Condensers, some deposit inside the tubes (contamination factor) is a normal effect that must be considered when selecting the product. The risk of deposits is reduced when using heat-exchanging tubes of low contamination factor.
Brand Name
Supply Capacity
1000 units per month
Condition of Goods
Lead Time from Order to Shipment
25-45 days
Model Number
Minimum Order Quantity
Power Requirements
up to buyer
Terms of Payment
L/C at sight or T/T
Terms of Sale
FOB GuangZhou
Warranty Coverage